HOME
 
 
ROTRACK
 
 
WHO
IS PSI
 
 
CROSSFLOW
 
 
CASE
STUDIES
 
 
SAMPLE
SCREENS
 
 
CONTACT
PSI
 
Process Scientific, Inc.

Reverse Osmosis TRACKing System
SPECIFICATIONS MODEL 1200

RELATED TOPICS

What is RoTrack
Application & Uses

 
Monitoring Services
Overview
Benefits

 
Components Overview

 
Monitoring Services
Overview
Benefits

 
Specifications
Model 1100

 

Sensor Interface Module
Model 1200

The RoTRACK Sensor Interface Module (SIM) is a complete, stand alone hardware package that accepts the sensor inputs and converts them to digital signals. The data can be stored at a user defined interval in the on board datalog memory. Each SIM contains a battery backup system that retains data in the event of power failure. Two serial ports are provided for either RS232 or RS422/485 communications. Multiple SIMs can be connected in a daisy chain fashion to provide additional monitoring capabilities. Multiple SIMs can be connected in a daisy chain fashion to provide additional monitoring capabilities.

INPUTS - ANALOG
Number: 26
Resolution: 10 bit (1023 steps)
Ranges: 0 - 10 vdc
                 0 - 5 vdc
                 0 - 2 vdc
                 0 - 1 vdc
                 4 -20 ma

INPUTS - PULSE
Number: 8
Range: 0-5 volt TTL
Pull Up Resistors: 10K Ohm
Maximum Frequency: 1500 Hz

INPUTS - RESISTANCE
Number:2
Compatibility: 100 ohm RTD

INPUTS - ACCUMULATOR
Contact closure input initiates pulse to accumulator for tracking run hours.
Number: 2

INPUTS - DIGITAL
Number: 16
Type: High/Low State
Result: 0, 1

MEMORY
Datalog Memory: 20K
Program Memory: 4K

COMMUNICATIONS
Serial Ports: 2
Type: RS232 or RS422
Baud: 300 to 19,200

POWER
Power Supply: 12 volt, 1.7 amp
Primary Backup: 12v, Approx 20 hr
Secondary Backup: 3v, Memory Only

PHYSICAL
Operating Temperature: -36 to +70 deg C
Enclosures: NEMA 4
Dimensions: 26.5" x 12" x 8"